GaitAI · SecureVision

GaitAI ReID

Track the same person across cameras — by gait.

ReID estimates cross-camera correspondence using body- and movement-level signatures — for authorized investigation and operational continuity when appearance changes, faces are unavailable or cameras capture people from a distance.

Request a pilot
GaitAI ReID
Input
Multi-camera views
Analysis
Movement signatures
Output
Candidate trails
User
Authorized investigator
01

Problem

Cross-camera continuity is difficult when appearance changes, faces are unavailable or cameras capture people from a distance.

02

What GaitAI does

Gait and body-level movement signatures link candidate observations across cameras, producing confidence-scored trails and camera-transition maps for human review.

03

Who uses it

  • Airports and rail networks
  • Large campuses
  • Enterprise investigation teams
  • Authorized security operations
04

What they receive

Cross-camera trailMovement signatureConfidence scoreTimelineCamera transition map
Confidence-scored
Match model
Human-confirmed
Final decision
Case-scoped
Authorization
Audited
Match history

Example report values — illustrative, not measured performance claims.

Results are confidence-based candidate matching, not infallible identity proof. A trail is a hypothesis for an investigator to verify against other evidence.

05

Why it matters

Continuity across cameras — the question every multi-camera investigation asks — becomes a ranked, reviewable hypothesis instead of hours of manual matching.

06

Example workflow

  1. 01Authorized case defines the tracked subject and scope
  2. 02Movement signatures are computed per observation
  3. 03Candidate matches link observations across cameras
  4. 04Each link carries a confidence score
  5. 05Investigator confirms or rejects each candidate
07

Deployment

  • Case-scoped, access-controlled operation
  • Confidence thresholds configured per deployment
  • Every match logged for audit
  • Runs under PrivacyGuard policy gates
08

Research basis

09

Evidence status

GaitAI Evidence Index

2 categories documented

What is documented for this module, and what is not. Research foundation is not product validation — the two are listed separately on purpose.

Research foundationAvailable
5 published records directly address a capability this module is built on (Gait recognition & biometrics).
View evidence for Research foundation
Architectural research relationshipNot yet published
No further shared-platform research relationship is recorded beyond the research foundation above.
View evidence for Architectural research relationship

Claim / capability: No further shared-platform research relationship is recorded beyond the research foundation above.

Status: Not yet published

Applicability: Shared capabilities such as pose estimation or temporal modelling are used by many modules.

Limitation: A shared-platform relationship is the weakest research link and must not be read as validating this module.

No supporting source is published for this status.

Inventory reviewed .

Product specificationAvailable
The module has a documented specification: inputs, pipeline, outputs and stated limitations.
View evidence for Product specification

Claim / capability: The module has a documented specification: inputs, pipeline, outputs and stated limitations.

Status: Available

Applicability: Documented inputs, intended workflow and output design.

Limitation: Documentation does not establish a released implementation or deployment readiness.

Inventory reviewed .

Product implementation evidenceNot yet published
No module-specific release or deployment record is published here.
View evidence for Product implementation evidence

Claim / capability: No module-specific release or deployment record is published here.

Status: Not yet published

Applicability: Production implementation is distinct from this website's interactive prototypes.

Limitation: The browser pose explorer is not the full clinical or operational product pipeline.

Inventory reviewed .

Interactive demoNot yet published
No sample output has been built for this module yet.
View evidence for Interactive demo

Claim / capability: No sample output has been built for this module yet.

Status: Not yet published

Applicability: An interactive explanation of the intended output and workflow.

Limitation: Sample outputs contain illustrative values and are not measurements of a visitor or product performance.

No supporting source is published for this status.

Inventory reviewed .

Benchmark validationNot yet published
Validation pending publication. No product benchmark numbers are supplied.
View evidence for Benchmark validation

Claim / capability: Validation pending publication. No product benchmark numbers are supplied.

Status: Not yet published

Applicability: A benchmark needs a defined dataset, sample count, environment, hardware and evaluation method.

Limitation: Accuracy, sensitivity, specificity, latency and FPS cannot be inferred from a demonstration.

Inventory reviewed .

Product-specific validationNot yet published
No study in the published record evaluates this module's output for a particular intended use.
View evidence for Product-specific validation

Claim / capability: No study in the published record evaluates this module's output for a particular intended use.

Status: Not yet published

Applicability: Validation must match the module, population and intended decision.

Limitation: A product description or related research paper does not establish validated performance.

Inventory reviewed .

Pilot & deployment evidenceNot yet published
No named pilot, deployment result or customer outcome is documented.
View evidence for Pilot & deployment evidence

Claim / capability: No named pilot, deployment result or customer outcome is documented.

Status: Not yet published

Applicability: Pilot and deployment evidence is assessed separately from research.

Limitation: Use-case journeys describe intended workflows, not customer results.

Inventory reviewed .

Product-specific clinical validationNot yet published
No product-specific clinical validation study is published in this library.
View evidence for Product-specific clinical validation

Claim / capability: No product-specific clinical validation study is published in this library.

Status: Not yet published

Applicability: Clinical applicability depends on the intended use; safety modules are not presented as clinical tools.

Limitation: No output replaces clinician judgement or establishes a diagnosis.

Inventory reviewed .

Regulatory clearanceNot claimed
No medical-device clearance, regulatory approval or compliance status is claimed.
View evidence for Regulatory clearance

Claim / capability: No medical-device clearance, regulatory approval or compliance status is claimed.

Status: Not claimed

Applicability: Regulatory applicability depends on the intended use and deployment jurisdiction.

Limitation: Research publications, patents and prototypes are not regulatory clearances.

Inventory reviewed .

Inventory reviewed How GaitAI states evidence →

10

Privacy & responsible use

Designed to support consent-based capture, encrypted transfer, configurable retention and role-based access, with activity logging and skeleton-only processing modes. Deployment requirements depend on the applicable environment, organization and jurisdiction. Privacy-aware architecture does not automatically mean anonymity: pose, gait and trajectories may still carry identifying information. Movement analytics are designed to run without identifying individuals unless a deployment lawfully and explicitly requires it, and identity-related capabilities are intended only for lawful, authorized deployments with appropriate governance, access control and auditability. Outputs are decision support for trained operators — not autonomous enforcement. Watchlist, ReID, AccessMotion and ForensicSearch require documented lawful authority, consent where applicable, purpose-limited access, audit logs and human review. Candidate associations are not proof of identity and must not trigger automatic denial, enforcement or adverse decisions.

Context & limitations
  • Confidence-based candidates — not identity proof
  • Signature quality varies with viewpoint and capture conditions
  • Restricted to authorized, case-scoped use under policy
GaitAI · ReID

Discuss a pilot with your team.